Area reduction by using different read port for div*/rem* instruction…
Created by: Silabs-ArjanB
…s; sequentially equivalent change
Changed register file prot usage for DIV*/REM* instructions to avoid usage of 3rd register file read port. The change reduces area and is sequentially equivalent.