ModBus
ModBus
######
######
`Modbus <https://modbus.org/>` is a communication protocol from the 1970s
`Modbus <https://modbus.org/>`__ is a communication protocol from the 1970s
designed to support industrial use cases. Its main modes of operation are Modbus
designed to support industrial use cases. Its main modes of operation are Modbus
RTU (Remote Terminal Unit) and Modbus TCP. The RTU variant is mostly used over
RTU (Remote Terminal Unit) and Modbus TCP. The RTU variant is mostly used over
RS-485 serial ports, while the newer Modbus TCP variant allows for a communication
RS-485 serial ports, while the newer Modbus TCP variant allows for a communication
@@ -19,8 +19,9 @@ into homes e.g. in home heating systems and PV systems.
@@ -19,8 +19,9 @@ into homes e.g. in home heating systems and PV systems.
|main_project_name| maintains support for Modbus in its Linux and Zephyr
|main_project_name| maintains support for Modbus in its Linux and Zephyr
flavours. On the Linux side the user-space Modbus implementation `libmodbus
flavours. On the Linux side the user-space Modbus implementation `libmodbus
<https://libmodbus.org/>` is used while on Zephyr the native `Modbus subsystem
<https://libmodbus.org/>`__ is used while on Zephyr the native `Modbus
<https://docs.zephyrproject.org/latest/services/modbus/index.html>` is used.
subsystem <https://docs.zephyrproject.org/latest/services/modbus/index.html>`__
 
is used.
RTU and TCP operation modes are supported.
RTU and TCP operation modes are supported.
@@ -46,7 +47,7 @@ following line to your `conf/local.conf` file:
@@ -46,7 +47,7 @@ following line to your `conf/local.conf` file:
On Zephyr you would need to enable the `CONFIG_MODBUS` options for your modes of
On Zephyr you would need to enable the `CONFIG_MODBUS` options for your modes of
operations. The Zephyr upstream project does offer `samples for RTU as well as
operations. The Zephyr upstream project does offer `samples for RTU as well as
TCP operations modes in different roles
TCP operations modes in different roles
<https://github.com/zephyrproject-rtos/zephyr/tree/main/samples/subsys/modbus>`
<https://github.com/zephyrproject-rtos/zephyr/tree/main/samples/subsys/modbus>`__
Modbus-testing
Modbus-testing
**************
**************
@@ -55,7 +56,7 @@ The `libmodbus` library does not come with any examples on how to use it by
@@ -55,7 +56,7 @@ The `libmodbus` library does not come with any examples on how to use it by
default. To fill this gap and allow integrators and developers to have a
default. To fill this gap and allow integrators and developers to have a
head-start when developing an application using `libmodbus` we developed a small
head-start when developing an application using `libmodbus` we developed a small
set of examples to demonstrate the usage. These examples can be found at our
set of examples to demonstrate the usage. These examples can be found at our
`modbus-testing repo <https://gitlab.eclipse.org/stefanschmidt/modbus-testing>`
`modbus-testing repo <https://gitlab.eclipse.org/stefanschmidt/modbus-testing>`__
and included in the image by the following addition to your `conf/local.conf` file:
and included in the image by the following addition to your `conf/local.conf` file:
.. code-block::
.. code-block::